MISMMS Advisory 10-second Constant-item Cadence
This MISB ST 0902 temporal rule provides an advisory check for constant-item cadence using MISB ST 0601 Tag 2 timestamps.
The rule watches these commonly constant items:
- Tag 3: Mission ID
- Tag 10: Platform Designation
- Tag 11: Image Source Sensor
- Tag 12: Image Coordinate System
- Tag 94: Motion Imagery Core Identifier
The rule warns when any of these items goes longer than 10 seconds without a non-zero-length report.
This rule is warning-only because the 10-second cadence guidance is informative rather than normative.